Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 49
Filter
1.
Article | IMSEAR | ID: sea-222446

ABSTRACT

The Rationale: “Frozen Eye” is a very uncommon sequel after treatment of orbital blowout fractures requiring implant placement. Patient Concerns: The implant may faultily impinge on the ocular and extra?ocular muscle(s), causing the abnormality in the movement of the eye. Diagnosis: We present a 56?year?old male whose ocular implant impinged on muscle, causing “frozen eye” and had an infected implant. Treatment Outcomes: The same was removed and surgically corrected. The manuscript describes the details and discusses the possible mechanism that led to the “Frozen Eye”

2.
Archives of Orofacial Sciences ; : 259-267, 2022.
Article in English | WPRIM | ID: wpr-964060

ABSTRACT

ABSTRACT @#The main aim of orbital fracture reconstruction is to restore the functional and aesthetic components of the eye. However, it is known that surgery for complex three-dimensional anatomy of the orbit is always a challenge. With recent advancements in technology, surgical predictability and outcomes have greatly improved. Several methods for orbital reconstruction surgery have been documented such as virtual surgical planning, intraoperative navigation, intraoperative imaging, and the use of patient-specific implant (PSI). PSI made of titanium can be designed by using a computer-aided design process and manufacturing (CAD-CAM) of CT-scan routinely used during diagnostic imaging. With precise analyses in shape and size followed by personalised implant design, the surgical precision can be alleviated further and at the same time, the surgical duration could be reduced with anticipation of better surgical outcomes. However, meticulous planning needs to be done preoperatively, with the timing of the surgery being an important factor. In the present case, pure orbital blowout fracture primarily treated with a personalised-implant solution derived from 3D-printing technology is described. Both pre-surgical and surgical workflow of this computer-assisted surgical method is elaborated. PSI for primary orbital reconstruction can be regarded as a viable alternative surgical solution including its working timeframe and adherence to the surgical protocol or algorithm.


Subject(s)
Orbital Implants
3.
Archives of Orofacial Sciences ; : 1-12, 2021.
Article in English | WPRIM | ID: wpr-962114

ABSTRACT

ABSTRACT@#Intraoperative computed tomography (CT) has been previously described and acknowledged for its use in orbital blowout fracture reconstructions. We described a clinical case series managed by this technique combined with intraoperative image fusion for accuracy in orbital implant position. In total, eight patients who sustained a total number of 19 orbital wall fractures were described. From the total number of 19 blowout orbital fracture reconstructions comprised of medial and inferior (floor) orbital fractures, malposition was identified in a total of four orbital implants by using image fusion. All cases of implant malposition were immediately revised intraoperatively. Subsequent fusion was carried out to confirm whether the revision was satisfactorily achieved. We found that the intraoperative image fusion technique utilised to determine orbital implant position, especially at the posterior ledge, further augmented the role of intraoperative CT scanning. Image fusion conceptually provides an immediate, real-time, and objective solution for intraoperative image analysis and potentially eliminates problems with misaligned CT images. It also reduces the need for the surgeon to ‘eye-ball’ the CT images acquired or the need for additional intraoperative time, since the patient’s head orientation is always axially at random during the acquisition of the CT. Conventional methods for CT image assessment are subjected to one’s own interpretation and may introduce inconsistent or longer intraoperative decision-making. The technique facilitates intraoperative decision-making and reduces the risk of orbital implant malposition in orbital blowout fracture reconstructions. Hence, surgical complication in relation to orbital implant malposition in orbital blowout fracture management could be minimised. In addition, no further postoperative imaging is required.


Subject(s)
Orbital Fractures , Tomography, X-Ray Computed
4.
Journal of the Korean Ophthalmological Society ; : 117-124, 2020.
Article in Korean | WPRIM | ID: wpr-811332

ABSTRACT

PURPOSE: To report the clinical manifestations and computed tomography (CT) findings of patients with a trapdoor type medial orbital wall blowout fracture.METHODS: From March 2009 to October 2016, the clinical records and computed tomography findings of patients who underwent surgical treatment for a trapdoor type medial orbital wall blowout fracture were retrospectively analyzed.RESULTS: A total of eight patients (six males and two females) were enrolled with a combined mean age of 14.4 years. Clinical manifestations were eyeball movement limitation (abduction and adduction) and ocular motility pain (eight patients, 100%), diplopia (seven patients, 87.5%), and nausea and vomiting (four patients, 50%). On CT, the distance from the orbital apex to the fracture site was an average of 22.0 mm and occurred in the middle position of the entire wall. Two patients had missed rectus completely dislocated into the ethmoid sinus through the fracture gap and six patients had definite involvement in the fracture gap and edema of the medial rectus muscle. The medial rectus muscle cross-sectional area was 47.7 mm² which was edematous compared to the contralateral eye (40.1 mm²). Orbital wall reconstruction was performed an average of 4.1 days after the injury. In all patients with oculocardiac reflex-like nausea and vomiting immediately improved after surgery. Six out of eight patients who had eyeball movement limitations (abduction and adduction) preoperatively showed adduction limitation after surgery. The eyeball movement limitation and diplopia disappeared 11.7 days and 46.7 days after surgery, respectively.CONCLUSIONS: Patients with trapdoor type medial wall blowout fracture showed characteristic computed tomographic findings and clinical manifestations such as eyeball movement limitation, ocular motility pain, diplopia, and oculocardiac reflex. An understanding of clinical findings and quick surgical treatment are therefore required. The type of eyeball movement limitation was abduction and adduction limitation preoperatively and adduction limitation postoperatively.


Subject(s)
Humans , Male , Diplopia , Edema , Ethmoid Sinus , Nausea , Orbit , Reflex, Oculocardiac , Retrospective Studies , Vomiting
6.
International Eye Science ; (12): 577-581, 2019.
Article in Chinese | WPRIM | ID: wpr-731868

ABSTRACT

@#AIM:To investigate the effect of conjunctival approach and skin approach on postoperative complications in orbital blowout fracture through Meta-analysis.<p>METHODS: Search literatures in PubMed, Web of Science, Cochrane library, OVID, Chinese biomedical literature database, Weipu, Wanfang and CNKI database from the establishment of the database to May 30, 2018. The main contents included randomized controlled trials and cohort studies about comparing the postoperative complications of orbital blowout fracture through the transconjunctival approach and subciliary approach. Meta-analysis of the incidence of complications was performed using Review Manager 5.3 statistical software.<p>RESULTS: A total of 7 cohort studies were included. The Newcastle Ottawa Scale(NOS)score showed that the quality of the included literature was above 6 points. Meta-analysis showed no significant difference in odds ratio(OR)between the transconjunctival approach group and subciliary approach group \〖<i>OR</i>=0.74, 95% <i>CI </i>(0.44-1.24),<i> P=</i>0.25\〗. Sensitivity analysis showed that the results of the Meta-analysis were stable and reliable. Funnel plot analysis showed that there might be publication bias in the included literature.<p>CONCLUSION: The effect of skin approach and conjunctival approach on the incidence of postoperative complications of orbital blowout fractures is not significant. The two approaches have their own advantages and disadvantages. It is necessary to combine the clinical practical considerations to select the most suitable surgical approach.

7.
Recent Advances in Ophthalmology ; (6): 290-294, 2018.
Article in Chinese | WPRIM | ID: wpr-699605

ABSTRACT

As one of the common type of ocular injuries,orbital fracture can result in enophthalmos,diplopia and infraorbital nerve injury,which affects the physiological function of eyeball.Repairing surgery for orbital fracture should be treated for reconstructing the orbital anatomical structure in case of severe enophthalmos and diplopia,or infraorbital nerve injury.Meanwhile,it's crucial to identify the suitable surgery approach and implants because of the specificity and complexity of the orbit.What a clinician expected most is the ideal prognosis obtained easily with minimal operation complication.Transconjunctival approach should be applied as one of the standard approaches for repairing surgery of orbital fracture,offering good operative field with less complications.Titanium mesh and resorbable materials are the ideal implants at present,for their high level of stable quality and plasticity.More and more applications of 3D-printed rapid prototyping technique can guide the new directions of individualization and precision of repairing surgery for orbital fracture.

8.
Journal of Medical Postgraduates ; (12): 407-410, 2016.
Article in Chinese | WPRIM | ID: wpr-486100

ABSTRACT

Objective This study was to evaluate the clinical outcomes of orbital blowout fracture repair using the individual titanium mesh bent by computer-aided rapid prototyping . Methods The CT imaging data of 11 cases of orbital blowout fracture were analyzed.The subciliary approach was used for the exposure of the fractures .An appropriate 3D-printed titanium mesh pre-bent by computer-aided rapid prototyping was selected and implanted according to the characteristics of a given defect .The surgical results were analyzed by evaluating diplopia , eyeball movement , enophthalmos , and the position of the titanium mesh and comparing the orbital vol-ume before and after surgery . Results All the operations were successfully accomplished .No remolding or trimming was needed for the pre-bent titanium mesh and implanted titanium mesh was tightly fixed to the orbital wall .The patients were followed up for 3 -12 months, which revealed no symptoms of diplopia in any of the patients . Volumetric analysis showed a significantly reduced orbital volume difference from (2.60 ±0.43) mL preoperatively to (-0.07 ±0.62) mL postoperatively (P<0.01).Enophthalmos was desirably correc-ted, with the enophthalmos difference decreased from (2.35 ±0.81)mm preoperatively to (-0.10 ±0.52) mm postoperatively (P<0.01).No extra-ocular muscle limitation was observed . Conclusion The individual titanium mesh bent with computer-aided rapid prototyping technology can be applied to orbital blowout fracture repair , which may achieve a high success rate of anatomic restoration of the orbital volume and effective prevention of enophthalmos .

9.
Journal of the Korean Ophthalmological Society ; : 1282-1286, 2016.
Article in Korean | WPRIM | ID: wpr-79920

ABSTRACT

PURPOSE: To help predict the severity of ocular complications in orbital blunt trauma by analyzing clinical features of ocular complications and orbital wall fracture. METHODS: A retrospective survey consisting of 169 eyes of 168 patients with orbital blunt trauma who visited Kosin University Gospel Hospital was performed. The patients' age, gender, height, weight, cause of accident, and ocular complications were investigated. The patients were imaged using computer tomography and divided into two groups according to whether they had orbital wall fracture: the orbital contusion group and the orbital wall fracture group. Variables of orbital wall fracture, including the location, length, width, and area were measured using computer tomography in the orbital wall fracture group. RESULTS: The incidence of ocular complication was 27 of 67 eyes (40.2%) in the orbital wall fracture group and 75 of 102 eyes (73.5%) in the orbital contusion group; ocular complications were found significantly more often in the orbital contusion group than in the orbital wall fracture group (p < 0.001). Among causes of the accident, 'flying object' showed the highest incidence of ocular complication at 40 of 48 eyes (85.1%). In the orbital wall fracture group, there was no significant difference in orbital fracture location, length, width or area between the ocular complication group and the non-ocular complication group. CONCLUSIONS: Ocular complications were found significantly more often in the orbital contusion group than in the orbital wall fracture group, and 'flying object' showed the highest incidence of ocular complication among causes of the accident.


Subject(s)
Humans , Contusions , Incidence , Orbit , Orbital Fractures , Retrospective Studies
10.
Journal of the Korean Ophthalmological Society ; : 533-539, 2016.
Article in Korean | WPRIM | ID: wpr-135871

ABSTRACT

PURPOSE: To evaluate the effect of orbital wall reconstruction with absorbable osteoconductive unsintered hydroxyapatite/poly L-lactide by assessment of the orbital volume via orbital computed tomography. METHODS: 24 patients who followed up at least 6 months after orbital wall reconstruction with unsintered hydroxyapatite/poly L-lactide were included. Retrospective clinical chart reviews for clinical manifestations and complications were performed, and orbital volume measurements were taken using the Eclipse Treatment Planning System (ver.13.0, Varian Medical System Inc., Palo Alto, CA, USA) through orbital computed tomography, which were taken before operation, right after operation, and at last follow up. RESULTS: Fourteen patients (58.3%) showed diplopia and extraocular muscle movement limitation preoperatively. Diplopia was resolved at last follow up and extraocular muscle movement limitation was improved at postoperative 6 months for all cases. The mean volumes of the fractured orbit and the unaffected orbit before operation were 23.62 ± 0.45 cm3 and 21.95 ± 1.01 cm3, respectively (p = 0.003). The mean volumes of the fractured orbit and the unaffected orbit right after operation were 21.65 ± 0.91 cm3 and 21.78 ± 0.83 cm3, respectively (p = 0.542). The mean volumes of the fractured orbit and the unaffected orbit at last follow up were 21.84 ± 0.93 cm3 and 21.81 ± 0.91 cm3, respectively (p = 0.889). CONCLUSIONS: Absorbable osteoconductive unsintered hydroxyapatite/poly L-lactide was effective for clinical improvement and orbital volume assessment in cases of orbital wall reconstruction and it can be used safely without definite implant related complications.


Subject(s)
Humans , Absorbable Implants , Diplopia , Follow-Up Studies , Orbit , Retrospective Studies
11.
Journal of the Korean Ophthalmological Society ; : 533-539, 2016.
Article in Korean | WPRIM | ID: wpr-135866

ABSTRACT

PURPOSE: To evaluate the effect of orbital wall reconstruction with absorbable osteoconductive unsintered hydroxyapatite/poly L-lactide by assessment of the orbital volume via orbital computed tomography. METHODS: 24 patients who followed up at least 6 months after orbital wall reconstruction with unsintered hydroxyapatite/poly L-lactide were included. Retrospective clinical chart reviews for clinical manifestations and complications were performed, and orbital volume measurements were taken using the Eclipse Treatment Planning System (ver.13.0, Varian Medical System Inc., Palo Alto, CA, USA) through orbital computed tomography, which were taken before operation, right after operation, and at last follow up. RESULTS: Fourteen patients (58.3%) showed diplopia and extraocular muscle movement limitation preoperatively. Diplopia was resolved at last follow up and extraocular muscle movement limitation was improved at postoperative 6 months for all cases. The mean volumes of the fractured orbit and the unaffected orbit before operation were 23.62 ± 0.45 cm3 and 21.95 ± 1.01 cm3, respectively (p = 0.003). The mean volumes of the fractured orbit and the unaffected orbit right after operation were 21.65 ± 0.91 cm3 and 21.78 ± 0.83 cm3, respectively (p = 0.542). The mean volumes of the fractured orbit and the unaffected orbit at last follow up were 21.84 ± 0.93 cm3 and 21.81 ± 0.91 cm3, respectively (p = 0.889). CONCLUSIONS: Absorbable osteoconductive unsintered hydroxyapatite/poly L-lactide was effective for clinical improvement and orbital volume assessment in cases of orbital wall reconstruction and it can be used safely without definite implant related complications.


Subject(s)
Humans , Absorbable Implants , Diplopia , Follow-Up Studies , Orbit , Retrospective Studies
12.
Journal of the Korean Ophthalmological Society ; : 961-966, 2015.
Article in Korean | WPRIM | ID: wpr-73381

ABSTRACT

PURPOSE: To report a case of pediatric medial wall blowout fracture with entrapment of medial rectus muscle which can be easily misdiagnosed as a cerebral lesion. CASE SUMMARY: A 16-year-old male visited our clinic with headache, severe restriction of his right eye movement, and diplopia after a head injury due to falling occurring 1 day before evaluation. The patient was inebriated at the time of the accident and could not recall the event but occipital hematoma was palpable. Periorbital ecchymosis or edema was not observed with minimal soft tissue injury except mild conjunctival injection on slit-lamp examination. The patient had an 18 prism diopter exodeviation at primary position and severe medial and mild lateral gaze limitation in his right eye. Brain magnetic resonance imaging (MRI) showed no specific cerebral findings although trapdoor orbital medial wall fracture with incarceration of soft tissue and medial rectus muscle at the medial wall fracture site of his right eye was observed. Within 48 hours from the first evaluation, the blowout fracture was repaired and 50 days postoperatively, right eye gaze limitation and diplopia were nearly recovered. CONCLUSIONS: A case of pediatric blowout fracture with uncertain injury location, periocular ecchymosis, or edema absent could be misdiagnosed as a cerebral lesion. If a pediatric patient is experiencing gaze limitation, diplopia, nausea, or vomiting after trauma, neurological examination as well as evaluation for blowout fracture should be performed.


Subject(s)
Adolescent , Humans , Male , Brain , Craniocerebral Trauma , Diplopia , Ecchymosis , Edema , Exotropia , Eye Movements , Headache , Hematoma , Magnetic Resonance Imaging , Nausea , Neurologic Examination , Orbit , Soft Tissue Injuries , Vomiting
13.
Korean Journal of Otolaryngology - Head and Neck Surgery ; : 246-249, 2012.
Article in Korean | WPRIM | ID: wpr-644473

ABSTRACT

The most possible complication of transnasal reconstruction of medial orbital wall fracture is infection of the dependent sinuses. As a result, endoscopic reduction in a medial blowout fracture with sinusitis and nasal polyp has been avoided. The silastic sheet and Merocel packing, which are placed in the ethmoid sinus, may cause or worsen sinusitis since they could cover up the natural ostia in the vicinity of sinuses. The spread of infection into the orbital wall and the difficulty of recognizing between herniated orbital tissues, infection and nasal polyp makes it difficult to perform endoscopic reduction when there are concomitant sinusitis and nasal polyp. The author reports three recently encountered cases of endoscopic reduction of medial blowout fracture with sinusitis and nasal polyp.


Subject(s)
Dimethylpolysiloxanes , Ethmoid Sinus , Formaldehyde , Nasal Polyps , Orbit , Polyvinyl Alcohol , Sinusitis
14.
Journal of the Korean Ophthalmological Society ; : 613-617, 2012.
Article in Korean | WPRIM | ID: wpr-204913

ABSTRACT

PURPOSE: To investigate the frequency of significant intraocular sequelae (SIOS) in orbital blunt trauma and their association with blowout and facial bone fractures. METHODS: A retrospective survey consisting of 726 patients with orbital blunt trauma who visited Korea University Medical Center was performed. Patients were divided into three groups: blowout fracture only group (group 1), facial bone fracture group (nasal bone fracture, maxillary fracture, zygoma fracture without blowout fracture, group 2), and non-fracture group (group 3). SIOS (traumatic iridocyclitis, commotio retina, hyphema, retinal hemorrhage, eyeball rupture, vitreous hemorrhage, retinal detachment, lens dislocation, traumatic cataract) were surveyed in each group, and the association between the frequency of SIOS and the presence of blowout fracture or facial bone fracture was analyzed. RESULTS: The frequency of SIOS in the fracture groups was 83.8% in group 1 and 73.3% in group 2, which were both higher than the 67.9% in group 3, the non-fracture group (p = 0.000 by chi-square linear by linear association). Traumatic iridocyclitis and hyphema were also significantly higher in groups 1 and 2 than group 3 (p = 0.003, p = 0.008 by chi-square linear by linear association). CONCLUSIONS: SIOS was found significantly more often in the fracture group than the group without fracture, although the frequency of severe SIOS was lower in the fracture group than the non-fracture group. The results from the present study could help in the treatment and management of patients with orbital blunt trauma.


Subject(s)
Humans , Academic Medical Centers , Facial Bones , Fractures, Bone , Hyphema , Iridocyclitis , Korea , Lens Subluxation , Maxillary Fractures , Orbit , Retina , Retinal Detachment , Retinal Hemorrhage , Retrospective Studies , Rupture , Vitreous Hemorrhage , Zygoma
15.
Journal of the Korean Ophthalmological Society ; : 902-909, 2011.
Article in Korean | WPRIM | ID: wpr-145483

ABSTRACT

PURPOSE: To analyze the morphologic differences in blowout fracture seen on preoperative CT images compared to intraoperative images. METHODS: The present study included 63 patients (63 eyes) with orbital fractures that were repaired by orbital reconstruction between January 2009 and April 2010. We assessed the medial, inferior, and inferomedial orbital fractures and excluded superior and lateral wall fractures. We captured intraoperative blowout fracture images using a camera or endoscope and compared the fracture type (fracture size, fracture surface) seen on intraoperative images with that observed on the preoperative CT images. RESULTS: The study consisted of patients between 20 and 50 years of age with a mean age of 27.76 years (men: 49 eyes, women: 14 eyes). The proportions of small fractures and medium fractures were similar on the preoperative CT images; however, large fractures were observed more frequently on the intraoperative images. The proportions of mono-fragment fractures and multi-fragment fractures were similar on the preoperative CT images, but multi-fragment fractures, especially inferior orbital fractures, were more frequent on the intraoperative images. Features of the trapdoor fracture differed most between images in terms of fracture size and surface. CONCLUSIONS: The morphology of blowout fractures, especially trapdoor fractures, differed between preoperative CT images and intraoperative images.


Subject(s)
Humans , Endoscopes , Eye , Orbit , Orbital Fractures
16.
Journal of the Korean Association of Oral and Maxillofacial Surgeons ; : 205-213, 2011.
Article in Korean | WPRIM | ID: wpr-35336

ABSTRACT

INTRODUCTION: The enlargement and deformation of the orbit give rise to a visible enophthalmos. As a consequence, a disturbance of eye motility together with double images is likely to occur. This study examined the degree of enophthalmos according to the extent of orbital wall fracture and volume of herniated orbital tissue in blowout fractures of the medial and inferior orbital wall. MATERIALS AND METHODS: This study was performed on patients diagnosed with medial and inferior orbital wall fractures at the Department of Oral and maxillofacial surgery, Chonbuk National University Hospital from 2007 to 2009. The patients' age, gender, etiology of fracture and degree of enophthalmos were investigated. The changes in the degree of enophthalomos, diplopia and ocular motility restriction after operation were examined. RESULTS: The degree of enophthalomos increased with increasing extent of orbital wall fracture and volume of herniated orbital tissue. CONCLUSION: Whether to perform the operation is decided after measuring the extent of the orbital wall fracture and volume of herniated orbital tissue using computed tomography (CT), time for the decision of operation can be shortened. This can cause a decrease in the complications of orbital wall fractures.


Subject(s)
Humans , Diplopia , Enophthalmos , Eye , Orbit , Surgery, Oral
17.
Journal of the Korean Ophthalmological Society ; : 639-643, 2011.
Article in Korean | WPRIM | ID: wpr-199092

ABSTRACT

PURPOSE: To report a case of inferior oblique muscle overaction after orbital trauma. CASE SUMMARY: A 19-year-old male presented with a blowout fracture of the right inferior orbital wall. The patient had no history of facial asymmetry, head tilt, strabismus or diplopia. The day after the reduction operation, the patient complained of diplopia on the down-gaze. The patient had orhthophoria in the primary position. However, the right eye showed a limitation on infraduction. Six weeks later, the limitation of infraduction resolved, however the diplopia worsened. The right eye showed excessive elevation in adduction and hypertropia in the primary position. The hypertropia increased on left gaze, and decreased on right gaze. Bielschowsky's head test revealed a negative result. The fundus photographs showed a mild excyclotorsion of the right eye. Five months later, the symptoms and signs were stable and surgery was performed. Under general anesthesia, the exaggerated forced duction test and traction with strabismus hook on the right inferior oblique muscle revealed tightness. The inferior oblique muscle was found to be recessed. After the operation, the diplopia, hypertropia and the excessive elevation on adduction of the right eye resolved. CONCLUSIONS: A contracture and resultant overaction of inferior oblique muscle could develop after trauma on the inferior orbital wall. Trauma on the inferior orbital wall should be considered as one of the primary causes of acquired inferior oblique overaction.


Subject(s)
Humans , Male , Young Adult , Anesthesia, General , Contracture , Diplopia , Eye , Facial Asymmetry , Head , Muscles , Orbit , Strabismus , Traction
18.
Journal of the Korean Cleft Palate-Craniofacial Association ; : 7-12, 2010.
Article in Korean | WPRIM | ID: wpr-219160

ABSTRACT

PURPOSE: 'White-eye blowout' fracture is often occur in young patients and defined as blow out fracture with little or no clinical sign of soft tissue trauma such as edema, ecchymosis, but with marked motility restrictions in vertical gaze. In this conditions, immediate operation is essential. We reported the clinical investigation study of these cases about clinical symptoms and radiologic findings and introduce our experiences about immediate operations in 'white-eye blowout' fractures. METHODS: From January 2008 to December 2009, nine pediatric patients who were diagnosed as pure white-eye blowout fractures were involved this study. Patients with other facial bone fractures or with poor general medical condition were excluded. In all cases, we performed immediate operation within 48 hours. RESULTS: All patients had diplopia, vertical gaze restriction or systemic symptoms. Six patients had nausea, vomiting and syncope caused by oculocardiac reflex. In all patients, preoperative symptoms were improved after immediate operation. There were no postoperative complications such as infection, hematoma or wound dehiscence. CONCLUSION: When we meet the young patients with history of periocular trauma, with little or no soft tissue trauma signs, but with marked vertical gaze restriction or general symptoms caused by oculocardiac reflex, we should immediately examine by facial bone computed tomography and refer the patient to ophthalmologist for ophthalmic evaluations. If patient is diagnosed as orbital floor fracture with entrapped muscle or soft tissue, the earlier surgical reduction get better clinical outcomes.


Subject(s)
Humans , Diplopia , Ecchymosis , Edema , Facial Bones , Floors and Floorcoverings , Hematoma , Muscles , Nausea , Orbit , Postoperative Complications , Reflex, Oculocardiac , Syncope , Vomiting
19.
Journal of the Korean Society of Plastic and Reconstructive Surgeons ; : 619-625, 2010.
Article in Korean | WPRIM | ID: wpr-34348

ABSTRACT

PURPOSE: Trapdoor orbital blowout fracture is most common in orbital blowout fracture. Various materials have been used to reconstruct orbital floor blowout fracture. Absorbable alloplastic implants are needed because of disadvantages of nonabsorbable alloplastic materials and donor morbidity of autogenous tissue. The aim of the study is to evaluate usefulness of absorbable mesh plate as a reconstructive material for orbital blowout fractures. METHODS: From December 2008 to October 2009, 18 trapdoor orbital floor blowout fracture patients were treated using elevator fixation, depressor fixation, or elevator-depressor fixation techniques with absorbable mesh plates and screw, depending on degree of orbital floor reduction, because absorbable mesh plates are less rigid than titanium plates and other artificial substitutes. RESULTS: Among 18 patients, 5 elevator fixation, 4 depressor fixation, and 9 elevator and depressor fixation technique were performed. In all patients, postoperative computed tomographic (CT) scan showed complete reduction of orbital contents and orbital floor, and no displacement of bony fragment and mesh plate. Mean follow-up was 10 months. There were no significant intraoperative or postoperative complications. CONCLUSION: Three different techniques depending on the degree of orbital floor reduction are useful for open reduction and internal fixation of trapdoor orbital floor blowout fracture with absorbable mesh plates.


Subject(s)
Humans , Displacement, Psychological , Elevators and Escalators , Floors and Floorcoverings , Follow-Up Studies , Orbit , Postoperative Complications , Tissue Donors , Titanium
20.
Journal of the Korean Cleft Palate-Craniofacial Association ; : 85-90, 2010.
Article in Korean | WPRIM | ID: wpr-109523

ABSTRACT

PURPOSE: The goals of a blow-out fracture reconstruction are to restore the osseous continuity, provide support for the orbital contents and prevent functional and anatomic defects. Over the past several years, a range of autogenous and synthetic implants have been used extensively in orbital reconstructions. None of these implants have any absolute indications or contraindications in certain clinical settings. However, in extensive blow-out fractures, it is difficult to restore support of the orbital contents, which can cause more complications, such as enophthalmos. This study examined the clinical outcomes of extensive or comminuted blow-out fractures that were reconstructed by the simultaneous use of a titanium mesh plate and Medpor(R). METHODS: Eighty six patients with extensive orbital fractures, who were admitted between March 1999 and February 2007, were reviewed retrospectively. The patients' chart and CT were inspected for review. Twenty three patients were operated on with both a titanium mesh plate (Matrix MIDFACE pre-formed orbital plate, Synthes, USA) and Medpor(R) (Porex, GA, USA). The patients underwent pre-operative CT scans to evaluate the fracture site and measure the area of the fracture. A transconjunctival approach was used, and titanium mesh plates were inserted subperiosteally with screw fixation. Medpor(R) was inserted above the titanium mesh plate. The patients were evaluated post-operatively for enophthalmos, diplopia, sensory disturbances and eyeball movement for a period of at least 6 months. RESULTS: No implant-related complications were encountered during the follow-up period. Enophthalmos occurred in 1 patient, 1 patient had permanent sensory disturbance, and 3 patients complained of ocular pain and fatigue, which recovered without treatment. Although there were no significance differences between groups, the use of 2 implants had fewer complications. Therefore, it can be an alternative method for treating blow out fractures. CONCLUSION: The use of both a titanium mesh plate and Medpor(R) simultaneously may be a safe and acceptable technique in the reconstruction of extensive blow-out fractures.


Subject(s)
Humans , Diplopia , Enophthalmos , Fatigue , Follow-Up Studies , Orbit , Orbital Fractures , Polyethylene , Retrospective Studies , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL